圖書館空調(diào)解決方案

 海洛斯恒溫恒濕空調(diào)    |      2016-04-06
針對(duì)圖書館場(chǎng)所的空調(diào)解決方案,由于圖書館無明顯發(fā)熱設(shè)備,且對(duì)溫濕控制及節(jié)能有較高要求。根據(jù)圖書館場(chǎng)所的特點(diǎn),空調(diào)選型推薦為:HIMOD M41機(jī)型。
The solution for a library is equipped with higher requirements for temperature and humidity control and energy saving because of the no heating in the room. According to the characteristics of the space for the library, the selection of model is recommended as HIMOD M41.
經(jīng)濟(jì)效益評(píng)估:(Economic Evaluation)
  • 該圖書館需安裝空調(diào)面積總計(jì)100平方米左右,圖書館無發(fā)熱設(shè)備,且對(duì)溫濕控制及節(jié)能有要求。依據(jù)實(shí)際情況每平米所需制冷量平均按350W計(jì)算,總需求的35KW制冷量。
The total area is of about 100 square meters for the library, and there is no heating source, and it requires the temperature and humidity control and energy saving features. Required cooling capacity per square meter on average calculated based on the actual situation according to 350W, the total demand for cooling capacity is of 35KW.
  • 要滿足該項(xiàng)目35KW的制冷量,需使用HIMOD M41機(jī)組1套裝機(jī)。
To meet the cooling capacity of 35KW, this project is needed to use one set of unit (HIMOD M41).
  • 經(jīng)濟(jì)效益對(duì)比估算:傳統(tǒng)空調(diào)滿足35KW制冷量的輸入功率至少為12KW左右,而HIMOD M41機(jī)組1套主機(jī)的輸入功率合計(jì)為7.4KW,主機(jī)部分省電38.3%,全年共計(jì)節(jié)省電費(fèi)0.9萬元以上。(按1年運(yùn)行8個(gè)月,1月運(yùn)行30天,1天運(yùn)行8小時(shí),用電按1元1度計(jì)算)
Comparison of economic benefit estimation: the traditional air-conditioning input power (35KW cooling capacity) is at least about 12KW, and the HIMOD M41 input power per set is of 7.4KW. The energy saving is up to 38.3%. The annual saving is more than 9000 CNY. (According to 8 months per year, 30 days per month, 8 hours per day of operation, electricity by 1 CNY/1 degree calculation)
精密空調(diào) 機(jī)房精密空調(diào)