通訊機房空調(diào)解決方案

 海洛斯精密空調(diào)    |      2016-04-06
針對通訊機房的空調(diào)解決方案,通訊機房的特點為訊息傳遞工作場所,通訊機房有大量發(fā)熱設備,通訊機房內(nèi)人員不會太多。根據(jù)通訊機房的特點,空調(diào)選型推薦如下:I52機型。
This is a solution of A/C for a communication room. The characteristic of the communication room is the workplace in data transmission facility, and there is a large amount of equipment. Personnel are not too much. According to the characteristics of the space for the communication room, the selection of model is recommended as I52.
經(jīng)濟效益評估:(Economic Evaluation)
  • 該通訊機房需安裝空調(diào)面積總計100平方米左右,有大量發(fā)熱設備(10KW),對溫濕控制及節(jié)能有要求,依據(jù)實際情況每平米所需制冷量平均按400W計算,總需求50KW制冷量。
The total area is of about 100 square meters for the communication room, and there is a large amount of heat source (10KW), and it requires the temperature and humidity control and energy saving features. Required cooling capacity per square meter on average calculated based on the actual situation according to 400W, the total demand for cooling capacity is of 50KW.
  • 要滿足該項目50KW的制冷量,需使用I52機組1套裝機。
To meet the cooling capacity of 50KW, this project is needed to use one set of unit (I52).
  • 經(jīng)濟效益對比估算:傳統(tǒng)空調(diào)滿足50KW制冷量的輸入功率至少為18KW左右,而I52機組1套主機的輸入功率合計為12.15KW,主機部分省電32.5%,全年共計節(jié)省電費1.1萬元以上。(按1年運行8個月,1月運行30天,1天運行8小時,用電按1元1度計算) 精密空調(diào) 機房精密空調(diào)
Comparison of economic benefit estimation: the traditional air-conditioning input power (50KW cooling capacity) is at least about 18KW, and the I52 input power per set is of 12.15KW. The energy saving is up to 32.5%. The annual saving is more than 11000 CNY. (According to 8 months per year, 30 days per month, 8 hours per day of operation, electricity by 1 CNY/1 degree calculation)