As everyone knows, the heavy load (w/m2) in computer applications is mainly caused by the increasing loads of data center racks and it finally produces heat load density which is relatively high. Because of unpredictable heavy loads, the remarkable performance of cooling system is required, at the same time occupies small space, so as provides more space for equipment in the room.
眾所周知,機房應(yīng)用中的負(fù)載負(fù)荷(w/m2)不斷的上升,主要是由數(shù)據(jù)中心機架負(fù)荷的增加而造成,最終產(chǎn)生了比較高的熱負(fù)荷密度。這要求空調(diào)系統(tǒng)具有更卓越的性能,同時盡可能占小的空間,從而為機房設(shè)備提供更大的空間。
Air-Blade has the advantage of energy saving in the market of air-conditioning because the space is the same as the value.
Air-Blade是市場上最具節(jié)能性的空調(diào)。 因為空間意味著價值。
Blade series is applicable for the server (horizontal blower type) with a surrounding air inlet and split system.It can meet the needs of a new generation of computer room and server center refrigeration standard. The refrigeration density for the blade series is very high (on the surface of 0.8mm2 reaches as high as 25KW). By using the modularized design including adaptive logic system can be managed through network, and the blade series is the best partner for the architecture of blade server and high density equipment. It is the ideal refrigeration system for the telephone, internet, data center, service center, and high density of buildings.
刀片風(fēng)用在服務(wù)器上(水平送風(fēng)式)有一款周圍進(jìn)氣和風(fēng)分體機系統(tǒng),可滿足新一代計算機房和服務(wù)器中心制冷標(biāo)準(zhǔn)。具有極高的制冷密度(在0.8mm2的表面上 高達(dá)25KW)。采用模坱化設(shè)計,包含自適應(yīng)羅輯系統(tǒng),可通過連網(wǎng)進(jìn)行管理,是刀片服務(wù)器架構(gòu)和高密度設(shè)備的最佳合作伙伴,是成為電話局、數(shù)據(jù)中心、互聯(lián) 網(wǎng)、服務(wù)中心和高密度建筑物的理想制冷系統(tǒng)。
Characteristicfor Air-Blade (刀片風(fēng)的特點):
Precision air inlet: Air volume can be controlled automatically according to the heat load and the needs of airflow;
精密送風(fēng):按需求送風(fēng),風(fēng)量可根據(jù)熱負(fù)荷自動控制;
Thenearest air inlet: The nearest air inlet and channelized closed system can achieve precise control of airflow;
就近送風(fēng):與信道封閉系統(tǒng)配合,使用可實現(xiàn)氣流精密可控;
Fan with energy saving: The distance of wind blowing is short, the air circulation resistance is small, and the power consumption of the fan isless;
風(fēng)機節(jié)能:送風(fēng)距離短,送回風(fēng)循環(huán)風(fēng)阻小,風(fēng)機功耗小;
Refrigeration system with energy saving: It can be matched with the channelized closed system, used to work at the high temperature environment, and is highly efficient and energy saving;
制冷系統(tǒng)節(jié)能:可與信道封閉系統(tǒng)配合,使用在高回風(fēng)溫度下工作,高效節(jié)能;
Installation easily: There is no need to install ventilation system under the ground. The cooling system is installed inside the cabinet which sucks out the rear or valve of the heat from the machine. The cold air is passed through the cooling channel and out in the front side of machine. The equipment is capable of absorbing heat from the cooling channel. The cooling facility is also applicable to update and upgrade under the existing structure of regulations.
安裝簡易:在地板下無需安裝通氣和通風(fēng)系統(tǒng)。安裝在機柜內(nèi)便于冷卻,從而吸出后部或閥通道的熱氣來自于機器,所謂的冷道從前側(cè)放(冷卻后),設(shè)備可從冷通道吸熱氣冷卻,且也適用于更新和升級依據(jù)現(xiàn)有規(guī)定的結(jié)構(gòu)。
列間空調(diào)精密空調(diào) 機房精密空調(diào)


This chart is for reference only, the new design of components and structures for the unit will change depending on the actual situation.
此工程圖僅供參考,新機型所使用的元件及機組內(nèi)部的設(shè)計會根據(jù)實際狀況而有所變動。